Products  Insulation monitoring  Main circuits AC, 3(N)AC, DC, AC/DC

Main circuits AC, 3(N)AC, DC, AC/DC

DC main circuits
These are, for example, battery systems, solar systems or voltages generated via rectifiers.

AC/DC main circuits
AC systems with galvanically connected DC components such as converters, rectifiers or UPS systems.

A-ISOMETER® for AC > 230 V
A-ISOMETER® IR470LY
The A-ISOMETER® of the IR470LY series is designed to monitor the insulation resistance of unearthed AC and three-phase systems (IT systems) AC/3(N)AC 0…793 V. In combination with a coupling device, the Isometers can also be used for higher voltages. An external supply voltage allows de-energized systems to be monitored too.
A-ISOMETER® IR470LY2-4061
The A-ISOMETER® of the IR470LY2 series is designed to monitor the insulation resistance of unearthed AC and three-phase systems (IT systems) AC/3(N)AC 0…793 V. Two separately adjustable response values/alarm relays allow a distinction to be made between "prewarning" and "alarm". In combination with a coupling device the device series can be used for higher voltages.
A-ISOMETER® IR470LY2-60
The A-ISOMETER® of the IR470LY2 series is designed to monitor the insulation resistance of unearthed AC and three-phase systems (IT systems) AC/3(N)AC 0…793 V. The device series is particularly suitable for systems requiring a high insulation level. The device can also be used for monitoring de-energized loads.
A-ISOMETER® for AC, AC/DC or DC systems >230 V
A-ISOMETER® IRDH275
The A-ISOMETER® of the IRDH275 series is designed to monitor the insulation resistance of unearthed main circuits (IT systems) AC, AC/DC 0…793 V resp. DC 0…650 V. The AMPPlus measuring principle meets the particular requirements of modern power supplies which often include rectifiers, converters, thyristor-controlled DC drives and directly connected DC components.
A-ISOMETER® IRDH375
The A-ISOMETER® of the IRDH375(B) series is designed to monitor the insulation resistance of unearthed main circuits (IT systems) AC, AC/DC 0…793 V resp. DC 0…650 V. The AMPPlus measuring principle meets the particular requirements of modern power supplies which often include rectifiers, converters, thyristor-controlled DC drives and directly connected DC components. In these systems often high leakage capacitances against earth occur due to interference suppression measures.
A-ISOMETER® IR1575
The A-ISOMETER® of the IR1575 series is designed to monitor the insulation resistance of unearthed main circuits (IT systems) AC, AC/DC 30…480 V resp. DC 0…480 V. The AMP measuring principle allows the Isometers to be used in systems with directly connected DC components. The IR1575 automatically adapts itself to the existing system leakage capacitances. An external supply voltage allows de-energized systems to be monitored too.

Mailing Address   Telephone Details

Industrial Automation & Logics Solutions
Address : C-57 Ground Floor, Ganganagari,
Bhadrabad Industrial Area
City : Haridwar
State : UTTARAKHAND
Pin : 249402

Branch Office:
109/3/2,Street No-15,
Krishna Nagar, New Delhi
9997015752,9258039200


01334-214074,+91-9997015752, +91-9258039209, +91-9258039207,8,9

 

Email
info@ials.co.in
santosh.industrial@gmail.com
enq@ials.co.in


maintained by Reosys
Copyright © 2011 ials.co.in, All Right Reserved.